High-temperature steam sterilisation systems for healthcare applications
WE develops high-temperature steam sterilisation technologies to meet all operational requirements, in accordance with current regulations and the production capacities of hospitals, clinics and medical facilities of all sizes.
TOUJAN TRADING L.L.C
sterilisation & infection control ✦ Authorized distributors for world-leading brands ✦For over fifteen years, we have set the standard in steam sterilisation, delivering infection control solutions that hospitals and laboratories trust worldwide. Our saturated steam technology ensures the highest level of safety, meeting the strictest international regulations.
Sterilisation is key to HAI prevention. The CSSD cleans, prepares, sterilises and returns surgical supplies.
Hospital sterilisation uses saturated steam 105–140°C / up to 2.6 bar (EU Dir 93/42). A device is sterile when SAL <10⁻⁶.
Benchtop
Compact · low capacity — for clinics & satellite CSSDs.
- 105–140°C saturated steam
- Validated cycles for RMDs
- Space-saving
Freestanding
All sizes · high capacity — for central CSSDs.
- Up to 2.6 bar, pass‑through
- Compliant with EU Dir 93/42
- Custom configurations
TOUJAN TRADING L.L.C
Authorized agents for Cisa Group & international brands · steam sterilisation systems
P-200H SERIES
BENCHTOP SYSTEM- 18 – 75 liters
- Saturated steam
- Compact design
P-3000H & P-3600H
SMALL CAPACITY- 70 – 218 liters
- High-temp steam
- Ideal for clinics
P-420H & P-640H**
MEDIUM CAPACITY- 313 – 868 liters
- 4 ISO* · 255 L base
- NOVITA DI GAMMA
P-1000H SERIES
HIGH CAPACITY- 2790 / 5250 / 5580 L
- Large CSSD solutions
- Max throughput

23 LItre SUERIOR CISA P-240H
The 23 litre table top is the best value in its class.
The machine can be directly connected to a PC via a USB port on the rear, and also has a printer integrated in the control panel to record and store paper reports of each sterilisation cycle.
ENTRY LEVEL BENCHTOP SOLUTION
Benchtop sterilisation system CISA P-290H
Small steam steriliser complying with the latest regulatory and technical standards, compliant with UNI EN ISO 13060 Class B and PED 2014/68/EU for the reprocessing of surgical instruments, gloves and rubber materials and the treatment of liquids in open containers, empty glassware, flasks, test tubes, pipettes and Petri dishes.


P-290H: High production capacity benchtop sterilisation system
With its 77 litre chamber capacity, the P-290 is an ideal benchtop autoclave for healthcare facilities that require high productivity and maximum reliability. It is equipped with an autonomous chamber heating system by means of an electrically operated steam generator; it is complete with a pressure switch and pressure transducer to control the pressure and temperature inside the chamber. Vacuum is achieved by means of liquid ring pumps.
HIGH PERFORMANCE FOR DENTISTS
AND SUB STERILISATION
Small capacity saturated steam sterilisation system
P-3000H e P-3600H
The small production capacity Cisa Healthcare P-3000H and P-3600H Series autoclaves are ideal for clinics and healthcare environments with an operating room where maximum efficiency is required in a limited space.
They are the right answer for facilities handling around 2000 to 2500 operations per year.
Their optimised dimensions also make them ideal for the completion of large CSSD projects, where they can be combined with even more powerful technologies to achieve the desired production targets.
MODELS:
CISA P-3270 H
THE SMALL ONE IN THE RANGE, MADE JUST LIKE THE LARGE ONES
CISA P-3670 H
THE NARROWEST 2 SU ON THE MARKET
CISA P-3690 H
DEPTH LOADING WITHOUT SIDE ACCESS
NARROW AND FUNCTIONAL MODELS FROM 1 TO 3 SU
P-3270 H Mini
The Cisa P-3270 H Mini is equipped with a single door and has a circular sterilisation chamber that ensures excellent temperature distribution and a lightweight design. It allows the treatment of 1 SU with a fast cycle of less than half an hour.
MAXIMUM EFFICIENCY IN 30 MINUTES
Medium capacity high-temperature saturated steam sterilisation system
The P-420H and P640H series of medium production capacity saturated steam sterilisers for healthcare applications are stand-alone models ideal for clinics, healthcare environments and hospitals with a relatively high volume of operations.
Due to their medium to high capacity, these models are very often used in the design of CSSDs and central sterilisation services in hospitals.
Cisa’s medium capacity steam sterilisers are able to handle the reprocessing of RMDs generated by an average of 2 operating theatres (3,400 operations per year), getting to handle – with maximum capacity equipment of 12SU – up to 6 operating theatres (over 10 thousand operations per year).
It is possible to choose from a wide and versatile range of steam sterilisers with capacities ranging from 4 to 12 sterilisation units (and chamber volumes ranging from 255 to 868 litres).
Available in single door or double pass-through door versions, the wide range of models with different overall dimensions makes it possible to respond effectively to all customer requirements and to easily integrate the equipment itself into even the most complex projects.
The P-420 is an ideal freestanding solution in CSSDs and other areas dedicated to professional high-temperature steam reprocessing.
The P-640H is available in three different sizes, to design your spaces in the best possible way: the Standard version is 1175 cm wide, the Slim version is only 903 cm wide and the Large version is 1424 cm wide. It is also possible to request the chamber on the right or left side and manage the technical module and maintenance access accordingly.
P-420H
EFFICIENT STAND-ALONE FOR HIGHLY VERSATILE LOADS
P-640H LARGE
The large version of Cisa’s best seller
P-640H SLIM
ONE OF THE NARROWEST ON THE MARKET

P-640H Std
CISA BEST SELLER
JUST 1175 WIDE
VERSATILE AND EFFICIENT WITH LIMITED SPACE REQUIREMENTS
Large sized high-temperature saturated steam sterilisation system for sanitary applications [not yet H-certified].
These sterilisers range from 12 to 18 sterilisation units and are capable of meeting the reprocessing needs of at least 9 operating theatres handling more than 15 thousand operations per year.
The P-1000H Series equipment is available with a single door or with a horizontally sliding double pass-through door. It is possible to install these models flush with the floor by providing an ad hoc pit and specific loading accessories. The external trolley enters the chamber, which allows for an optimised supply of loading accessories.
The P-1000H series, with the same loading capacity as the P-640H, has half the depth of the P-640H, and this ensures ergonomics suited to the required high productivity by reducing the number of loads (by operators) and the number of cycles (of the machine).
serie P-1000H
961-1182-1478 Litri | 12-18 US
THE COMPLETION OF THE RANGE, FROM LIFE SCIENCE TO HEALTHCARE: FOR THE LAYOUT AND PRODUCTION NEEDS OF CONTEMPORARY HEALTHCARE ENVIRONMENTS

Sterilizing process traceability and data reporting
The sterilizers are supplied with
Printer
Internal memory
USB port
RJ45
connection port
The RJ45 connection port allows data transmission to advanced external tracking systems such as Cisa TRACECARE® is possible.
Tracecare® is the traceability system developed by Cisa Group which, in its full version, allows the management and monitoring of the kits’ process through the different areas (dirty area, clean area, sterile area) that make up the CSSD, helping to reduce clinical risk.
How are Cisa autoclaves different?

High reliability and durability |
|

Shorter cycles |
|

Compact design |
|

Easy to operate |
|

Eco-friendly technologies |
|

Highly customisable |
To suit your industry, your operational requirements & your site requirements |
Loading accessories for sterilisers
A wide range of loading accessories is available, made of AISI 304 steel and designed to customise the machine according to the different needs of the customer. They are also available with variable height and automatic loading/unloading devices designed for manual loading options such as internal loading trolleys with removable and adjustable shelves, or loading platforms and grids to make it easier for the operator to position the material inside the sterilisation chamber and retrieve it after the sterilisation process.
Loading.
Automatic loading and unloading devices with the use of a platform are designed to move the steriliser trolleys automatically. This function speeds up the loading process and frees the operator, who can remotely monitor the progress of the cycle (thanks to colour indicators), and carry out other activities within the CSSD.
It is possible to integrate the automatic loading and unloading system with a trolley return device (pass-through hatches) that allows the trolleys to be manoeuvred on the platform from the sterile area to the clean area of the CSSD in semi-automatic mode.
Cisa Group can supply the customer with classic stainless steel sterilisation containers in standard sizes.














Complete flexibility to wash, thermo-disinfect and dry all work tools in any healthcare environment.
Conformity of Cisa Group steam sterilization systems
The Cisa Group Sterilizers systems are in compliance with the following directives and laws, product manufactured under a quality system.









